Maximum number of verification intervals: nLC= 3000
Full Scale Output: 2mV/V ± 1%
Combined error: 0,017% of Full Scale Output (F.S.)
Non-Repeatability: 0,015% F.S.
Temperature effect on zero: ± 0,0014% /°C
Temperature effect on full scale output: ± 0,0014% /°C
Compensated Temperature Range: –10°C/+40°C
Operating Temperature Range: –20°C/+60°C
Creep error after 30 minutes ± 0,025% F.S.
Maximum tolerated excitation voltage: 15 VDC
Input Resistance: 385 ± 20 Ohm
Output Resistance: 350 ± 5 Ohm
Insulation Resistance: > 5000 MOhm
Safe Overload: 150% F.S.
Ultimate Overload: 200% F.S.
Nominal displacement: < 0,4 mm
4-wire shielded cable, 3m long, 4mm diameter.
ATEX VERSION
The CCATEX certificate makes the load cell suitable for use in hazardous areas with protection methods according to:
ATEX II 1G Ex ia IIC T6 (Ta -20÷+40°C) TX (Ta -20÷+65°C) Ga
ATEX II 1D Ex ta IIIC TX°C (Ta -20÷+40°C) TX°C (Ta -20÷+65°C) Da IP65.
The certificate includes the manual and the ATEX CE conformity declaration (available in EN, DE, FR, and IT).
IMPORTANT: the certificate refers to the single load cell. For systems with more load cells, it is necessary to order one certificate for each load cell.